Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System. 80 pp. Englisch. N° de réf. du vendeur 9786200284143
Quantité disponible : 2 disponible(s)
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 80 pages. 8.66x5.91x0.19 inches. In Stock. N° de réf. du vendeur zk6200284148
Quantité disponible : 1 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Katam Ganesh BabuDr. Ganesh Babu Katam born on 24th August 1983 in Kurnool (D), Andhra Pradesh, India. In 2009 he completed B.Tech in Mechanical Engg (IPE) from G. Pulla Reddy Engg College Kurnool. In the year 2011 received M.Tech de. N° de réf. du vendeur 385887243
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch. N° de réf. du vendeur 9786200284143
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System. N° de réf. du vendeur 9786200284143
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Two-Phase Ejector as a Performance Enhancer for Refrigeration Systems | Two-Phase Ejector as a Performance Enhancer for R134a Refrigerant used Vapour Compression Refrigeration System | Ganesh Babu Katam (u. a.) | Taschenbuch | 80 S. | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786200284143 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 117395313
Quantité disponible : 5 disponible(s)