Increased uses of nonlinear loads, encouragement to use distributed generations at the consumer premises make the power system fail to sustain quality of the supply. Due to this supply voltage and current becomes distorted and contain harmonics which is not good for machineries and applications used by industry, domestic and residential consumers. Among the different configurations of filters such as series, shunt and hybrid, shunt active power filter is considered in this research work. The actual behaviour of shunt active power filter lies with the proper control strategy. It is expected that the control strategy should take care of harmonic mitigation and power factor improvement with less complexity in controller implementation. Moreover the available control strategy takes care of mostly current harmonics and rarely in voltage harmonics. Furthermore only few research contributions have been made to mitigate the voltage harmonics in addition to current harmonics. A MATLAB model has been developed to simulate the system operation by considering different control schemes and simulation have been carried out and results are obtained under steady state and dynamic conditions.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : moluna, Greven, Allemagne
Etat : New. N° de réf. du vendeur 327230930
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26386672944
Quantité disponible : 4 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 393975535
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18386672954
Quantité disponible : 4 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Harmonics mitigation in distributed generation system | Performance investigation | Muhaidheen M. (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9786200433794 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 117578844
Quantité disponible : 5 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Increased uses of nonlinear loads, encouragement to use distributed generations at the consumer premises make the power system fail to sustain quality of the supply. Due to this supply voltage and current becomes distorted and contain harmonics which is not good for machineries and applications used by industry, domestic and residential consumers. Among the different configurations of filters such as series, shunt and hybrid, shunt active power filter is considered in this research work. The actual behaviour of shunt active power filter lies with the proper control strategy. It is expected that the control strategy should take care of harmonic mitigation and power factor improvement with less complexity in controller implementation. Moreover the available control strategy takes care of mostly current harmonics and rarely in voltage harmonics. Furthermore only few research contributions have been made to mitigate the voltage harmonics in addition to current harmonics. A MATLAB model has been developed to simulate the system operation by considering different control schemes and simulation have been carried out and results are obtained under steady state and dynamic conditions. N° de réf. du vendeur 9786200433794
Quantité disponible : 2 disponible(s)
Vendeur : Mispah books, Redhill, SURRE, Royaume-Uni
paperback. Etat : New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. N° de réf. du vendeur ERICA82962004337986
Quantité disponible : 1 disponible(s)