Concrete structures need post-fire analysis, because when exposed to high temperatures and to thermal shock by sudden cooling, they can present immeasurable damage, which is the subject proposed in the work. Therefore, besides comparing the values obtained with those of the reference CP's, they correlated with the data of the theoretical reference in order to verify the loss of resistance of the abruptly cooled concretes. The concrete with Fck of 35 and 40MPa presented higher loss of resistance, if compared to the concrete with Fck of 25MPa. At temperatures of 900 and 1200ºC, the percentage of loss is equal to the concrete with Fck of 25MPa. This refers to the fact that the more resistant the concrete is, the greater the percentage loss and the incidence of Explosive Spalling. In view of the results, it can be concluded that heating and cooling interfere with the physical-chemical properties and microstructure of the concrete, favoring the emergence of micro-cracks and consequently affecting the characteristic resistance of the concrete.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26397286796
Quantité disponible : 4 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Concrete structures need post-fire analysis, because when exposed to high temperatures and to thermal shock by sudden cooling, they can present immeasurable damage, which is the subject proposed in the work. Therefore, besides comparing the values obtained with those of the reference CP's, they correlated with the data of the theoretical reference in order to verify the loss of resistance of the abruptly cooled concretes. The concrete with Fck of 35 and 40MPa presented higher loss of resistance, if compared to the concrete with Fck of 25MPa. At temperatures of 900 and 1200ºC, the percentage of loss is equal to the concrete with Fck of 25MPa. This refers to the fact that the more resistant the concrete is, the greater the percentage loss and the incidence of Explosive Spalling. In view of the results, it can be concluded that heating and cooling interfere with the physical-chemical properties and microstructure of the concrete, favoring the emergence of micro-cracks and consequently affecting the characteristic resistance of the concrete. 84 pp. Englisch. N° de réf. du vendeur 9786200899576
Quantité disponible : 2 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 400138835
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18397286790
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Concrete structures need post-fire analysis, because when exposed to high temperatures and to thermal shock by sudden cooling, they can present immeasurable damage, which is the subject proposed in the work. Therefore, besides comparing the values obtained . N° de réf. du vendeur 493529406
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Concrete structures need post-fire analysis, because when exposed to high temperatures and to thermal shock by sudden cooling, they can present immeasurable damage, which is the subject proposed in the work. Therefore, besides comparing the values obtained with those of the reference CP's, they correlated with the data of the theoretical reference in order to verify the loss of resistance of the abruptly cooled concretes. The concrete with Fck of 35 and 40MPa presented higher loss of resistance, if compared to the concrete with Fck of 25MPa. At temperatures of 900 and 1200ºC, the percentage of loss is equal to the concrete with Fck of 25MPa. This refers to the fact that the more resistant the concrete is, the greater the percentage loss and the incidence of Explosive Spalling. In view of the results, it can be concluded that heating and cooling interfere with the physical-chemical properties and microstructure of the concrete, favoring the emergence of micro-cracks and consequently affecting the characteristic resistance of the concrete.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 84 pp. Englisch. N° de réf. du vendeur 9786200899576
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Concrete structures need post-fire analysis, because when exposed to high temperatures and to thermal shock by sudden cooling, they can present immeasurable damage, which is the subject proposed in the work. Therefore, besides comparing the values obtained with those of the reference CP's, they correlated with the data of the theoretical reference in order to verify the loss of resistance of the abruptly cooled concretes. The concrete with Fck of 35 and 40MPa presented higher loss of resistance, if compared to the concrete with Fck of 25MPa. At temperatures of 900 and 1200ºC, the percentage of loss is equal to the concrete with Fck of 25MPa. This refers to the fact that the more resistant the concrete is, the greater the percentage loss and the incidence of Explosive Spalling. In view of the results, it can be concluded that heating and cooling interfere with the physical-chemical properties and microstructure of the concrete, favoring the emergence of micro-cracks and consequently affecting the characteristic resistance of the concrete. N° de réf. du vendeur 9786200899576
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Behaviour of concrete exposed to high fire temperatures | Influence of thermal shock by sudden cooling | Adenilson Roberto Coelho (u. a.) | Taschenbuch | Englisch | 2020 | Our Knowledge Publishing | EAN 9786200899576 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 120428115
Quantité disponible : 5 disponible(s)