The control devices/switches in dc-dc converter are not ideal and these control devices are having energy losses which are conduction and switching losses. The switching losses are caused by the overlap of switch voltage and switch current in the switching transition period. Thus, this kind of switching can be referred to as hard switching, which specifies stressful switching behavior of converter switching devices. To overcome the disadvantages of hard switching, the soft switching converters have gained a great research interest. In this soft switching control strategy, the switching loss becomes zero by making either voltage across switch or current through switch is zero. the two-level single input multiple output isolated dc-dc converter is proposed for generating 2n-1 outputs where ‘n’ is number of legs, to reduce the space occupied by individual dc-dc converter systems. The efficiency of the proposed single input multiple output two-level isolated dc-dc converter has been compared with existing single input multiple output two-level dc-dc converter to realize the proposed work.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
J.Sivavara Prasad received the B.Tech from JNTU, Hyderabad (Electrical), M.Tech in Power and Industrial Drives from JNTU, Anantapur and submitted his Ph.D thesis to JNTU, Kakinada in the area of Switched mode resonant converters. Currently he is working as an Assoc. Professor in Dept. of EEE in L.B.R. College of Engineering,Mylavaram India
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The control devices/switches in dc-dc converter are not ideal and these control devices are having energy losses which are conduction and switching losses. The switching losses are caused by the overlap of switch voltage and switch current in the switching transition period. Thus, this kind of switching can be referred to as hard switching, which specifies stressful switching behavior of converter switching devices. To overcome the disadvantages of hard switching, the soft switching converters have gained a great research interest. In this soft switching control strategy, the switching loss becomes zero by making either voltage across switch or current through switch is zero. the two-level single input multiple output isolated dc-dc converter is proposed for generating 2n-1 outputs where 'n' is number of legs, to reduce the space occupied by individual dc-dc converter systems. The efficiency of the proposed single input multiple output two-level isolated dc-dc converter has been compared with existing single input multiple output two-level dc-dc converter to realize the proposed work. 52 pp. Englisch. N° de réf. du vendeur 9786202027311
Quantité disponible : 2 disponible(s)
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 52 pages. 8.66x5.91x0.12 inches. In Stock. N° de réf. du vendeur zk6202027312
Quantité disponible : 1 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Sivavara Prasad JJ.Sivavara Prasad received the B.Tech from JNTU, Hyderabad (Electrical), M.Tech in Power and Industrial Drives from JNTU, Anantapur and submitted his Ph.D thesis to JNTU, Kakinada in the area of Switched mode resonan. N° de réf. du vendeur 174172075
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -The control devices/switches in dc-dc converter are not ideal and these control devices are having energy losses which are conduction and switching losses. The switching losses are caused by the overlap of switch voltage and switch current in the switching transition period. Thus, this kind of switching can be referred to as hard switching, which specifies stressful switching behavior of converter switching devices. To overcome the disadvantages of hard switching, the soft switching converters have gained a great research interest. In this soft switching control strategy, the switching loss becomes zero by making either voltage across switch or current through switch is zero. the two-level single input multiple output isolated dc-dc converter is proposed for generating 2n-1 outputs where 'n' is number of legs, to reduce the space occupied by individual dc-dc converter systems. The efficiency of the proposed single input multiple output two-level isolated dc-dc converter has been compared with existing single input multiple output two-level dc-dc converter to realize the proposed work.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch. N° de réf. du vendeur 9786202027311
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The control devices/switches in dc-dc converter are not ideal and these control devices are having energy losses which are conduction and switching losses. The switching losses are caused by the overlap of switch voltage and switch current in the switching transition period. Thus, this kind of switching can be referred to as hard switching, which specifies stressful switching behavior of converter switching devices. To overcome the disadvantages of hard switching, the soft switching converters have gained a great research interest. In this soft switching control strategy, the switching loss becomes zero by making either voltage across switch or current through switch is zero. the two-level single input multiple output isolated dc-dc converter is proposed for generating 2n-1 outputs where 'n' is number of legs, to reduce the space occupied by individual dc-dc converter systems. The efficiency of the proposed single input multiple output two-level isolated dc-dc converter has been compared with existing single input multiple output two-level dc-dc converter to realize the proposed work. N° de réf. du vendeur 9786202027311
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Regulated Multiple Output Two-Level Isolated DC-DC Converter Topogies | J. Sivavara Prasad (u. a.) | Taschenbuch | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9786202027311 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 113378601
Quantité disponible : 5 disponible(s)