For sensorless control in the full speed range of PMSM, in the zero speed section and low speed section, the pulse vibration high frequency injection method is currently dominant. In this method, the parameter variations, inverse potential and cross-coupling terms have an impact on the rotor position estimation error, and the rotor position estimation error is obvious; in the medium and high speed sections, the sliding mode observer is currently dominant. Conventional counter potential sliding mode observer has a large amount of noise disturbance in the output counter potential due to its inherent jitter characteristics and measurement noise, and the use of low-pass filter makes the output counter potential have phase shift and amplitude weakening, which indirectly affects the estimation of rotor position and speed. The book combines the needs and practical experiences of sensorless control, and conducts research on several key issues in the full-speed range sensorless control of PMSM, and proposes several types of excellent rotor position estimation methods for permanent magnet synchronous motors and corresponding strategies to improve the rotor position estimation accuracy.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26403969682
Quantité disponible : 4 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -For sensorless control in the full speed range of PMSM, in the zero speed section and low speed section, the pulse vibration high frequency injection method is currently dominant. In this method, the parameter variations, inverse potential and cross-coupling terms have an impact on the rotor position estimation error, and the rotor position estimation error is obvious; in the medium and high speed sections, the sliding mode observer is currently dominant. Conventional counter potential sliding mode observer has a large amount of noise disturbance in the output counter potential due to its inherent jitter characteristics and measurement noise, and the use of low-pass filter makes the output counter potential have phase shift and amplitude weakening, which indirectly affects the estimation of rotor position and speed. The book combines the needs and practical experiences of sensorless control, and conducts research on several key issues in the full-speed range sensorless control of PMSM, and proposes several types of excellent rotor position estimation methods for permanent magnet synchronous motors and corresponding strategies to improve the rotor position estimation accuracy. 196 pp. Englisch. N° de réf. du vendeur 9786202309547
Quantité disponible : 2 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 409184589
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. For sensorless control in the full speed range of PMSM, in the zero speed section and low speed section, the pulse vibration high frequency injection method is currently dominant. In this method, the parameter variations, inverse potential and cross-couplin. N° de réf. du vendeur 628647925
Quantité disponible : Plus de 20 disponibles
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18403969688
Quantité disponible : 4 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Researches on Sensorless Control of PMSM in Full Speed Range | Haifeng Wei (u. a.) | Taschenbuch | Englisch | 2022 | Scholars' Press | EAN 9786202309547 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 122032873
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -For sensorless control in the full speed range of PMSM, in the zero speed section and low speed section, the pulse vibration high frequency injection method is currently dominant. In this method, the parameter variations, inverse potential and cross-coupling terms have an impact on the rotor position estimation error, and the rotor position estimation error is obvious; in the medium and high speed sections, the sliding mode observer is currently dominant. Conventional counter potential sliding mode observer has a large amount of noise disturbance in the output counter potential due to its inherent jitter characteristics and measurement noise, and the use of low-pass filter makes the output counter potential have phase shift and amplitude weakening, which indirectly affects the estimation of rotor position and speed. The book combines the needs and practical experiences of sensorless control, and conducts research on several key issues in the full-speed range sensorless control of PMSM, and proposes several types of excellent rotor position estimation methods for permanent magnet synchronous motors and corresponding strategies to improve the rotor position estimation accuracy.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 196 pp. Englisch. N° de réf. du vendeur 9786202309547
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - For sensorless control in the full speed range of PMSM, in the zero speed section and low speed section, the pulse vibration high frequency injection method is currently dominant. In this method, the parameter variations, inverse potential and cross-coupling terms have an impact on the rotor position estimation error, and the rotor position estimation error is obvious; in the medium and high speed sections, the sliding mode observer is currently dominant. Conventional counter potential sliding mode observer has a large amount of noise disturbance in the output counter potential due to its inherent jitter characteristics and measurement noise, and the use of low-pass filter makes the output counter potential have phase shift and amplitude weakening, which indirectly affects the estimation of rotor position and speed. The book combines the needs and practical experiences of sensorless control, and conducts research on several key issues in the full-speed range sensorless control of PMSM, and proposes several types of excellent rotor position estimation methods for permanent magnet synchronous motors and corresponding strategies to improve the rotor position estimation accuracy. N° de réf. du vendeur 9786202309547
Quantité disponible : 1 disponible(s)