A grounded guard trace inserted coupled line layout was proposed to reduce the far-end and near-end noise in the high-speed digital system. A unique methodology was introduced to determine the required no. of grounded vias on the guard trace to minimize the noise coupling. Optimal performance in the time and the frequency domain were obtained for the guard trace with 25 vias configuration. The far-end and the near-end noise voltage are reduced by 54%, 42% compared to the coupled line with 3W spacing. The MEO and MEW values are 0.8V, 0.39nsec respectively. From the scattering parameter results, an average isolation of -35dB for the far-end noise and -45dB for the near-end noise was obtained. The induced far-end and near-end noise voltage is only 0.63%, 0.75% of the signal swing in the active line.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A grounded guard trace inserted coupled line layout was proposed to reduce the far-end and near-end noise in the high-speed digital system. A unique methodology was introduced to determine the required no. of grounded vias on the guard trace to minimize the noise coupling. Optimal performance in the time and the frequency domain were obtained for the guard trace with 25 vias configuration. The far-end and the near-end noise voltage are reduced by 54%, 42% compared to the coupled line with 3W spacing. The MEO and MEW values are 0.8V, 0.39nsec respectively. From the scattering parameter results, an average isolation of -35dB for the far-end noise and -45dB for the near-end noise was obtained. The induced far-end and near-end noise voltage is only 0.63%, 0.75% of the signal swing in the active line. 52 pp. Englisch. N° de réf. du vendeur 9786204727080
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Karuppiah VasudevanVasudevan Karuppiah completed M.E in Wireless Technologies in 2005 from Thiagarajar College of Engineering, Tamilnadu, India. He obtained his PhD. in the field of EMI mitigation in High-speed digital circuits. His . N° de réf. du vendeur 541606476
Quantité disponible : Plus de 20 disponibles
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -A grounded guard trace inserted coupled line layout was proposed to reduce the far-end and near-end noise in the high-speed digital system. A unique methodology was introduced to determine the required no. of grounded vias on the guard trace to minimize the noise coupling. Optimal performance in the time and the frequency domain were obtained for the guard trace with 25 vias configuration. The far-end and the near-end noise voltage are reduced by 54%, 42% compared to the coupled line with 3W spacing. The MEO and MEW values are 0.8V, 0.39nsec respectively. From the scattering parameter results, an average isolation of -35dB for the far-end noise and -45dB for the near-end noise was obtained. The induced far-end and near-end noise voltage is only 0.63%, 0.75% of the signal swing in the active line.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch. N° de réf. du vendeur 9786204727080
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A grounded guard trace inserted coupled line layout was proposed to reduce the far-end and near-end noise in the high-speed digital system. A unique methodology was introduced to determine the required no. of grounded vias on the guard trace to minimize the noise coupling. Optimal performance in the time and the frequency domain were obtained for the guard trace with 25 vias configuration. The far-end and the near-end noise voltage are reduced by 54%, 42% compared to the coupled line with 3W spacing. The MEO and MEW values are 0.8V, 0.39nsec respectively. From the scattering parameter results, an average isolation of -35dB for the far-end noise and -45dB for the near-end noise was obtained. The induced far-end and near-end noise voltage is only 0.63%, 0.75% of the signal swing in the active line. N° de réf. du vendeur 9786204727080
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. CUSTOMIZED CROSSTALK NOISE SUPPRESSION PRACTICE IN HIGH-SPEED PCB | Vasudevan Karuppiah (u. a.) | Taschenbuch | Englisch | 2021 | LAP LAMBERT Academic Publishing | EAN 9786204727080 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 120955779
Quantité disponible : 5 disponible(s)