Pre-analytical requirements are specific to hemostasis. Failure to meet these requirements is often the reason for sample rejection. The number of rejected samples is a quality indicator and its monitoring is encouraged.Our objectives were to identify the main causes of rejection of haemostasis samples in the haematology laboratory of the Aziza Othmana Hospital and to propose appropriate corrective measures.We conducted a retrospective study of the 7299 requests for hemostasis examinations processed in the laboratory from 01/07/2020 to 30/06/2021. We recorded the number of rejected specimens as well as the identified non-compliances.The rejection rate was estimated at 5.63%. The non-compliance "Coagulated sample" was the first cause of rejection identified (45.93% of cases), followed by the reasons "Insufficient quantity" (22.08%) and "Hemolyzed sample" (15.73%).Our work is part of a quality improvement approach. It has enabled us to carry out an inventory of the causes of rejections in haemostasis and to propose appropriate corrective measures.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Books Puddle, Woodside, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26400922043
Quantité disponible : 4 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Pre-analytical requirements are specific to hemostasis. Failure to meet these requirements is often the reason for sample rejection. The number of rejected samples is a quality indicator and its monitoring is encouraged.Our objectives were to identify the main causes of rejection of haemostasis samples in the haematology laboratory of the Aziza Othmana Hospital and to propose appropriate corrective measures.We conducted a retrospective study of the 7299 requests for hemostasis examinations processed in the laboratory from 01/07/2020 to 30/06/2021. We recorded the number of rejected specimens as well as the identified non-compliances.The rejection rate was estimated at 5.63%. The non-compliance 'Coagulated sample' was the first cause of rejection identified (45.93% of cases), followed by the reasons 'Insufficient quantity' (22.08%) and 'Hemolyzed sample' (15.73%).Our work is part of a quality improvement approach. It has enabled us to carry out an inventory of the causes of rejections in haemostasis and to propose appropriate corrective measures. 52 pp. Englisch. N° de réf. du vendeur 9786204987460
Quantité disponible : 2 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 395455076
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18400922033
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Lamari HajerMedical biologist graduated from the Faculty of Medicine of Tunis,is interested in the different specialties of medical biology, especially in Immunology, Hematology and Qualitology.Pre-analytical requirements are spe. N° de réf. du vendeur 660938042
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Pre-analytical requirements are specific to hemostasis. Failure to meet these requirements is often the reason for sample rejection. The number of rejected samples is a quality indicator and its monitoring is encouraged.Our objectives were to identify the main causes of rejection of haemostasis samples in the haematology laboratory of the Aziza Othmana Hospital and to propose appropriate corrective measures.We conducted a retrospective study of the 7299 requests for hemostasis examinations processed in the laboratory from 01/07/2020 to 30/06/2021. We recorded the number of rejected specimens as well as the identified non-compliances.The rejection rate was estimated at 5.63%. The non-compliance 'Coagulated sample' was the first cause of rejection identified (45.93% of cases), followed by the reasons 'Insufficient quantity' (22.08%) and 'Hemolyzed sample' (15.73%).Our work is part of a quality improvement approach. It has enabled us to carry out an inventory of the causes of rejections in haemostasis and to propose appropriate corrective measures. N° de réf. du vendeur 9786204987460
Quantité disponible : 1 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Pre-analytical requirements are specific to hemostasis. Failure to meet these requirements is often the reason for sample rejection. The number of rejected samples is a quality indicator and its monitoring is encouraged.Our objectives were to identify the main causes of rejection of haemostasis samples in the haematology laboratory of the Aziza Othmana Hospital and to propose appropriate corrective measures.We conducted a retrospective study of the 7299 requests for hemostasis examinations processed in the laboratory from 01/07/2020 to 30/06/2021. We recorded the number of rejected specimens as well as the identified non-compliances.The rejection rate was estimated at 5.63%. The non-compliance 'Coagulated sample' was the first cause of rejection identified (45.93% of cases), followed by the reasons 'Insufficient quantity' (22.08%) and 'Hemolyzed sample' (15.73%).Our work is part of a quality improvement approach. It has enabled us to carry out an inventory of the causes of rejections in haemostasis and to propose appropriate corrective measures.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch. N° de réf. du vendeur 9786204987460
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Analysis of the causes of rejection of haemostasis samples | Hajer Lamari (u. a.) | Taschenbuch | Englisch | 2022 | Our Knowledge Publishing | EAN 9786204987460 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu. N° de réf. du vendeur 122298486
Quantité disponible : 5 disponible(s)