Plasticizers are commonly used in sensor fabrication to improve the mechanical properties and flexibility of the sensing materials. However, the choice of plasticizer can influence the performance and sensing characteristics of the biomimetic potentiometric sensor for atrazine. Different plasticizers can affect the sensitivity, selectivity, and response time of the sensor.The potential response of the sensor was studied using different plasticisers Dioctyl phthalate, DOP and Bis(2-ethyl hexyl)sebacate, BEHS. The sensor with BEHS shows a better Nernstian response in the range of 10-4 M - 10-8 M with a limit of detection 1×10-8 M and a slope of 56.2 mV. The newly created sensor has a dynamic response time of one minute and fifty seconds, and conditioning the sensor in a buffer containing 0.1 M acetic acid is necessary to obtain more accurate, repeatable findings.This study describes how plasticizers affected the design of a biomimetic potentiometric atrazine sensor.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26397337130
Quantité disponible : 4 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Plasticizers are commonly used in sensor fabrication to improve the mechanical properties and flexibility of the sensing materials. However, the choice of plasticizer can influence the performance and sensing characteristics of the biomimetic potentiometric sensor for atrazine. Different plasticizers can affect the sensitivity, selectivity, and response time of the sensor.The potential response of the sensor was studied using different plasticisers Dioctyl phthalate, DOP and Bis(2-ethyl hexyl)sebacate, BEHS. The sensor with BEHS shows a better Nernstian response in the range of 10-4 M - 10-8 M with a limit of detection 1×10-8 M and a slope of 56.2 mV. The newly created sensor has a dynamic response time of one minute and fifty seconds, and conditioning the sensor in a buffer containing 0.1 M acetic acid is necessary to obtain more accurate, repeatable findings.This study describes how plasticizers affected the design of a biomimetic potentiometric atrazine sensor. 52 pp. Englisch. N° de réf. du vendeur 9786205523513
Quantité disponible : 2 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 400121333
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18397337120
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Varghese SaumyaDr Saumya Varghese is an assistant professor in the PG and Research Department of chemistry, St Joseph s College (Autonomous), Devagiri, Calicut, India. She is recognised as research guide under University of Calicut K. N° de réf. du vendeur 892105165
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Plasticizers are commonly used in sensor fabrication to improve the mechanical properties and flexibility of the sensing materials. However, the choice of plasticizer can influence the performance and sensing characteristics of the biomimetic potentiometric sensor for atrazine. Different plasticizers can affect the sensitivity, selectivity, and response time of the sensor.The potential response of the sensor was studied using different plasticisers Dioctyl phthalate, DOP and Bis(2-ethyl hexyl)sebacate, BEHS. The sensor with BEHS shows a better Nernstian response in the range of 10-4 M - 10-8 M with a limit of detection 1×10-8 M and a slope of 56.2 mV. The newly created sensor has a dynamic response time of one minute and fifty seconds, and conditioning the sensor in a buffer containing 0.1 M acetic acid is necessary to obtain more accurate, repeatable findings.This study describes how plasticizers affected the design of a biomimetic potentiometric atrazine sensor. N° de réf. du vendeur 9786205523513
Quantité disponible : 1 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Plasticizers are commonly used in sensor fabrication to improve the mechanical properties and flexibility of the sensing materials. However, the choice of plasticizer can influence the performance and sensing characteristics of the biomimetic potentiometric sensor for atrazine. Different plasticizers can affect the sensitivity, selectivity, and response time of the sensor.The potential response of the sensor was studied using different plasticisers Dioctyl phthalate, DOP and Bis(2-ethyl hexyl)sebacate, BEHS. The sensor with BEHS shows a better Nernstian response in the range of 10-4 M - 10-8 M with a limit of detection 1×10-8 M and a slope of 56.2 mV. The newly created sensor has a dynamic response time of one minute and fifty seconds, and conditioning the sensor in a buffer containing 0.1 M acetic acid is necessary to obtain more accurate, repeatable findings.This study describes how plasticizers affected the design of a biomimetic potentiometric atrazine sensor.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch. N° de réf. du vendeur 9786205523513
Quantité disponible : 1 disponible(s)