Literature abounds with studies, concepts, controversies, discussions and recommendations concerning hinge axis. If the maxillary cast is positioned without the correct maxillae hinge axis relationship, arcs of movement in the articulator will differ from those of the patient. Like centric relation, hinge axis is stable, reproducible and repeatable. Therefore, it is used as an important reference in mounting casts on articulator so that, opening axis on articulator coincides with the terminal hinge axis. Since the hinge axis is a definite fixed component of every closing position of the mandible, it is necessary to reproduce it on the appropriate instrument. Verification of the mandibular cast position by using inter occlusal records made at increased vertical dimension of occlusion will be difficult or impossible unless subsequent records are of the same thickness. Also an occlusion that is restored to an incorrect arc of closure may have interceptive and deflective tooth contacts in the closing movement. The mounting of maxillary casts is considered important due to the influence of this step, on the arc of closure and eventual occlusal errors.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Literature abounds with studies, concepts, controversies, discussions and recommendations concerning hinge axis. If the maxillary cast is positioned without the correct maxillae hinge axis relationship, arcs of movement in the articulator will differ from those of the patient. Like centric relation, hinge axis is stable, reproducible and repeatable. Therefore, it is used as an important reference in mounting casts on articulator so that, opening axis on articulator coincides with the terminal hinge axis. Since the hinge axis is a definite fixed component of every closing position of the mandible, it is necessary to reproduce it on the appropriate instrument. Verification of the mandibular cast position by using inter occlusal records made at increased vertical dimension of occlusion will be difficult or impossible unless subsequent records are of the same thickness. Also an occlusion that is restored to an incorrect arc of closure may have interceptive and deflective tooth contacts in the closing movement. The mounting of maxillary casts is considered important due to the influence of this step, on the arc of closure and eventual occlusal errors. 168 pp. Englisch. N° de réf. du vendeur 9786205632871
Quantité disponible : 2 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. N° de réf. du vendeur 812875421
Quantité disponible : Plus de 20 disponibles
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Face bow and Hinge axis | Bhupendra Mal (u. a.) | Taschenbuch | Englisch | 2023 | LAP LAMBERT Academic Publishing | EAN 9786205632871 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand. N° de réf. du vendeur 126532170
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -Literature abounds with studies, concepts, controversies, discussions and recommendations concerning hinge axis. If the maxillary cast is positioned without the correct maxillae hinge axis relationship, arcs of movement in the articulator will differ from those of the patient. Like centric relation, hinge axis is stable, reproducible and repeatable. Therefore, it is used as an important reference in mounting casts on articulator so that, opening axis on articulator coincides with the terminal hinge axis. Since the hinge axis is a definite fixed component of every closing position of the mandible, it is necessary to reproduce it on the appropriate instrument. Verification of the mandibular cast position by using inter occlusal records made at increased vertical dimension of occlusion will be difficult or impossible unless subsequent records are of the same thickness. Also an occlusion that is restored to an incorrect arc of closure may have interceptive and deflective tooth contacts in the closing movement. The mounting of maxillary casts is considered important due to the influence of this step, on the arc of closure and eventual occlusal errors.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 168 pp. Englisch. N° de réf. du vendeur 9786205632871
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Literature abounds with studies, concepts, controversies, discussions and recommendations concerning hinge axis. If the maxillary cast is positioned without the correct maxillae hinge axis relationship, arcs of movement in the articulator will differ from those of the patient. Like centric relation, hinge axis is stable, reproducible and repeatable. Therefore, it is used as an important reference in mounting casts on articulator so that, opening axis on articulator coincides with the terminal hinge axis. Since the hinge axis is a definite fixed component of every closing position of the mandible, it is necessary to reproduce it on the appropriate instrument. Verification of the mandibular cast position by using inter occlusal records made at increased vertical dimension of occlusion will be difficult or impossible unless subsequent records are of the same thickness. Also an occlusion that is restored to an incorrect arc of closure may have interceptive and deflective tooth contacts in the closing movement. The mounting of maxillary casts is considered important due to the influence of this step, on the arc of closure and eventual occlusal errors. N° de réf. du vendeur 9786205632871
Quantité disponible : 1 disponible(s)