Objectives of the present work are to establish a new voltage stability index in radial distribution structure by considering distributed generators (DG). For fulfilment of this, analysis and study works were carried on for various types of loads with and without considering DG. One indicator is utilized to identify the proper location of distributed generator. For ideal size of DG an algorithm is proposed considering some constraints. After testing and analysis of this technique on medium size distribution network, it is concluded that placement of proper size of DG at optimal location the system has improved in terms of voltage level, decrease of losses and stability of the system. Here, maximum utilization of the existing system can be achieved by satisfying the customer with minimum frequency of failure and minimum duration of outage within the existing resources.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Objectives of the present work are to establish a new voltage stability index in radial distribution structure by considering distributed generators (DG). For fulfilment of this, analysis and study works were carried on for various types of loads with and without considering DG. One indicator is utilized to identify the proper location of distributed generator. For ideal size of DG an algorithm is proposed considering some constraints. After testing and analysis of this technique on medium size distribution network, it is concluded that placement of proper size of DG at optimal location the system has improved in terms of voltage level, decrease of losses and stability of the system. Here, maximum utilization of the existing system can be achieved by satisfying the customer with minimum frequency of failure and minimum duration of outage within the existing resources. 160 pp. Englisch. N° de réf. du vendeur 9786206147183
Quantité disponible : 2 disponible(s)
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26397360034
Quantité disponible : 4 disponible(s)
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Objectives of the present work are to establish a new voltage stability index in radial distribution structure by considering distributed generators (DG). For fulfilment of this, analysis and study works were carried on for various types of loads with and w. N° de réf. du vendeur 863316479
Quantité disponible : Plus de 20 disponibles
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 400065661
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18397360040
Quantité disponible : 4 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Development of New VSI of RDS by Using DGs and Its Reliable Operation | Development of New Voltage Stability Indicator of Radial Distribution Systems by Using DGs and Its Reliable Operation | Sumit Banerjee (u. a.) | Taschenbuch | Englisch | 2023 | LAP LAMBERT Academic Publishing | EAN 9786206147183 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de réf. du vendeur 126866352
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. Neuware -Objectives of the present work are to establish a new voltage stability index in radial distribution structure by considering distributed generators (DG). For fulfilment of this, analysis and study works were carried on for various types of loads with and without considering DG. One indicator is utilized to identify the proper location of distributed generator. For ideal size of DG an algorithm is proposed considering some constraints. After testing and analysis of this technique on medium size distribution network, it is concluded that placement of proper size of DG at optimal location the system has improved in terms of voltage level, decrease of losses and stability of the system. Here, maximum utilization of the existing system can be achieved by satisfying the customer with minimum frequency of failure and minimum duration of outage within the existing resources.Books on Demand GmbH, Überseering 33, 22297 Hamburg 160 pp. Englisch. N° de réf. du vendeur 9786206147183
Quantité disponible : 2 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Objectives of the present work are to establish a new voltage stability index in radial distribution structure by considering distributed generators (DG). For fulfilment of this, analysis and study works were carried on for various types of loads with and without considering DG. One indicator is utilized to identify the proper location of distributed generator. For ideal size of DG an algorithm is proposed considering some constraints. After testing and analysis of this technique on medium size distribution network, it is concluded that placement of proper size of DG at optimal location the system has improved in terms of voltage level, decrease of losses and stability of the system. Here, maximum utilization of the existing system can be achieved by satisfying the customer with minimum frequency of failure and minimum duration of outage within the existing resources. N° de réf. du vendeur 9786206147183
Quantité disponible : 1 disponible(s)