This study investigates the use of direct pumping systems in water supply networks using a PID control system to control pressure in water distribution networks, through a motor pump set driven by a frequency inverter. For this purpose, an experimental bench was used, simulating a real supply system (LENHS/UFPB). The hydro-energy efficiency of the direct pumping system was evaluated based on tests using the conventional scenario (without a controller) and employing the control system in situations of maximum and minimum demand. A case study was also conducted in the Pressure Zone of Reservoir R-11 (João Pessoa/PB) to verify that the implementation of the frequency inverter can generate hydroenergy gains in the supply system. The results obtained demonstrated the success of the controlled system, as the use of the controller coupled with the frequency inverter provided a reduction in operating pressures and water consumption. The results were also positive for the case study, as there were energy savings and reductions in the pressures supplied.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur L2-9786206750130
Quantité disponible : Plus de 20 disponibles
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. N° de réf. du vendeur I-9786206750130
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur L2-9786206750130
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This study investigates the use of direct pumping systems in water supply networks using a PID control system to control pressure in water distribution networks, through a motor pump set driven by a frequency inverter. For this purpose, an experimental bench was used, simulating a real supply system (LENHS/UFPB). The hydro-energy efficiency of the direct pumping system was evaluated based on tests using the conventional scenario (without a controller) and employing the control system in situations of maximum and minimum demand. A case study was also conducted in the Pressure Zone of Reservoir R-11 (João Pessoa/PB) to verify that the implementation of the frequency inverter can generate hydroenergy gains in the supply system. The results obtained demonstrated the success of the controlled system, as the use of the controller coupled with the frequency inverter provided a reduction in operating pressures and water consumption. The results were also positive for the case study, as there were energy savings and reductions in the pressures supplied. 52 pp. Englisch. N° de réf. du vendeur 9786206750130
Quantité disponible : 2 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 408315338
Quantité disponible : 4 disponible(s)
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. Print on Demand. N° de réf. du vendeur 26404871701
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18404871711
Quantité disponible : 4 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This study investigates the use of direct pumping systems in water supply networks using a PID control system to control pressure in water distribution networks, through a motor pump set driven by a frequency inverter. For this purpose, an experimental bench was used, simulating a real supply system (LENHS/UFPB). The hydro-energy efficiency of the direct pumping system was evaluated based on tests using the conventional scenario (without a controller) and employing the control system in situations of maximum and minimum demand. A case study was also conducted in the Pressure Zone of Reservoir R-11 (João Pessoa/PB) to verify that the implementation of the frequency inverter can generate hydroenergy gains in the supply system. The results obtained demonstrated the success of the controlled system, as the use of the controller coupled with the frequency inverter provided a reduction in operating pressures and water consumption. The results were also positive for the case study, as there were energy savings and reductions in the pressures supplied. N° de réf. du vendeur 9786206750130
Quantité disponible : 2 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. Energy Efficiency in Sanitation using Frequency Inverters | Arthur Brito Nunes Diniz | Taschenbuch | Englisch | 2025 | KS Omniscriptum Publishing | EAN 9786206750130 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu. N° de réf. du vendeur 132558614
Quantité disponible : 5 disponible(s)