A rapid method was developed for detecting biocides in textiles that come into direct contact with human skin, as recently regulated biocides lack validated testing methods. The method focuses on analyzing four biocides: MIT, CIT, OIT, and Triclosan. Textile samples were extracted using methanolic sonication, purified through centrifugation and filtration, and analyzed using a C18 column with 0.4% acetic acid: methanol (1:1 v/v) under isocratic conditions at 280 nm wavelength. Extraction parameters were optimized, and the calibration curve showed strong linearity (r² ≥ 0.9995) in the range of 1.0–5.0 mg L⁻¹. The method demonstrated high recoveries (95%–108%) with relative standard deviations ≤ 4%, while LODs and LOQs ranged from 0.06–0.12 mg L⁻¹ and 0.21–0.38 mg L⁻¹, respectively. The results confirmed the method's reliability for quantitative detection in real textile samples.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur L2-9786208433604
Quantité disponible : Plus de 20 disponibles
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. N° de réf. du vendeur I-9786208433604
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur L2-9786208433604
Quantité disponible : Plus de 20 disponibles
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9786208433604_new
Quantité disponible : Plus de 20 disponibles
Vendeur : Books Puddle, New York, NY, Etats-Unis
Etat : New. N° de réf. du vendeur 26404082745
Quantité disponible : 4 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A rapid method was developed for detecting biocides in textiles that come into direct contact with human skin, as recently regulated biocides lack validated testing methods. The method focuses on analyzing four biocides: MIT, CIT, OIT, and Triclosan. Textile samples were extracted using methanolic sonication, purified through centrifugation and filtration, and analyzed using a C18 column with 0.4% acetic acid: methanol (1:1 v/v) under isocratic conditions at 280 nm wavelength. Extraction parameters were optimized, and the calibration curve showed strong linearity (r 0.9995) in the range of 1.0-5.0 mg L . The method demonstrated high recoveries (95%-108%) with relative standard deviations 4%, while LODs and LOQs ranged from 0.06-0.12 mg L and 0.21-0.38 mg L , respectively. The results confirmed the method's reliability for quantitative detection in real textile samples. 60 pp. Englisch. N° de réf. du vendeur 9786208433604
Quantité disponible : 2 disponible(s)
Vendeur : Majestic Books, Hounslow, Royaume-Uni
Etat : New. Print on Demand. N° de réf. du vendeur 409104358
Quantité disponible : 4 disponible(s)
Vendeur : Biblios, Frankfurt am main, HESSE, Allemagne
Etat : New. PRINT ON DEMAND. N° de réf. du vendeur 18404082739
Quantité disponible : 4 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -A rapid method was developed for detecting biocides in textiles that come into direct contact with human skin, as recently regulated biocides lack validated testing methods. The method focuses on analyzing four biocides: MIT, CIT, OIT, and Triclosan. Textile samples were extracted using methanolic sonication, purified through centrifugation and filtration, and analyzed using a C18 column with 0.4% acetic acid: methanol (1:1 v/v) under isocratic conditions at 280 nm wavelength. Extraction parameters were optimized, and the calibration curve showed strong linearity (r ¿ 0.9995) in the range of 1.0-5.0 mg L¿ . The method demonstrated high recoveries (95%-108%) with relative standard deviations ¿ 4%, while LODs and LOQs ranged from 0.06-0.12 mg L¿ and 0.21-0.38 mg L¿ , respectively. The results confirmed the method's reliability for quantitative detection in real textile samples.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 60 pp. Englisch. N° de réf. du vendeur 9786208433604
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A rapid method was developed for detecting biocides in textiles that come into direct contact with human skin, as recently regulated biocides lack validated testing methods. The method focuses on analyzing four biocides: MIT, CIT, OIT, and Triclosan. Textile samples were extracted using methanolic sonication, purified through centrifugation and filtration, and analyzed using a C18 column with 0.4% acetic acid: methanol (1:1 v/v) under isocratic conditions at 280 nm wavelength. Extraction parameters were optimized, and the calibration curve showed strong linearity (r 0.9995) in the range of 1.0-5.0 mg L . The method demonstrated high recoveries (95%-108%) with relative standard deviations 4%, while LODs and LOQs ranged from 0.06-0.12 mg L and 0.21-0.38 mg L , respectively. The results confirmed the method's reliability for quantitative detection in real textile samples. N° de réf. du vendeur 9786208433604
Quantité disponible : 2 disponible(s)