Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9786209495076
Quantité disponible : Plus de 20 disponibles
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. N° de réf. du vendeur I-9786209495076
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. N° de réf. du vendeur L0-9786209495076
Quantité disponible : Plus de 20 disponibles
Vendeur : Grand Eagle Retail, Bensenville, IL, Etats-Unis
Paperback. Etat : new. Paperback. The application of the shear wall system in reinforced concrete (RC) buildings has become widely used to minimize seismic consequences.The present literature focuses on two different models with shear walls at different positions. The article showcases the parametric study in terms of displacement, storey drift, and base shear comparison for different location of shear wall in the building. The results are unique and fruitful for future attention. This paper focuses to see the effect of shear wall location in a multi-storied building. An in-plane building of G+10 (11 storey) structure having base dimension of 24m X 24m with typical floor height of 3.3m is considered. In this present work, a storied building was modeled using software and two different models were studied with different location of shear walls in building frame for critical parameters like displacement and base shear under lateral loading. The analysis has been carried out using the ETABS software and for analysis, seismic coefficient method is used. Two types of models (one with shear wall placed at middle of 4 periphery sides, one with shear wall placed at 4 corners in L shape) have been analyzed. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability. N° de réf. du vendeur 9786209495076
Quantité disponible : 1 disponible(s)
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 72 pp. Englisch. N° de réf. du vendeur 9786209495076
Quantité disponible : 2 disponible(s)
Vendeur : AussieBookSeller, Truganina, VIC, Australie
Paperback. Etat : new. Paperback. The application of the shear wall system in reinforced concrete (RC) buildings has become widely used to minimize seismic consequences.The present literature focuses on two different models with shear walls at different positions. The article showcases the parametric study in terms of displacement, storey drift, and base shear comparison for different location of shear wall in the building. The results are unique and fruitful for future attention. This paper focuses to see the effect of shear wall location in a multi-storied building. An in-plane building of G+10 (11 storey) structure having base dimension of 24m X 24m with typical floor height of 3.3m is considered. In this present work, a storied building was modeled using software and two different models were studied with different location of shear walls in building frame for critical parameters like displacement and base shear under lateral loading. The analysis has been carried out using the ETABS software and for analysis, seismic coefficient method is used. Two types of models (one with shear wall placed at middle of 4 periphery sides, one with shear wall placed at 4 corners in L shape) have been analyzed. This item is printed on demand. Shipping may be from our Sydney, NSW warehouse or from our UK or US warehouse, depending on stock availability. N° de réf. du vendeur 9786209495076
Quantité disponible : 1 disponible(s)
Vendeur : CitiRetail, Stevenage, Royaume-Uni
Paperback. Etat : new. Paperback. The application of the shear wall system in reinforced concrete (RC) buildings has become widely used to minimize seismic consequences.The present literature focuses on two different models with shear walls at different positions. The article showcases the parametric study in terms of displacement, storey drift, and base shear comparison for different location of shear wall in the building. The results are unique and fruitful for future attention. This paper focuses to see the effect of shear wall location in a multi-storied building. An in-plane building of G+10 (11 storey) structure having base dimension of 24m X 24m with typical floor height of 3.3m is considered. In this present work, a storied building was modeled using software and two different models were studied with different location of shear walls in building frame for critical parameters like displacement and base shear under lateral loading. The analysis has been carried out using the ETABS software and for analysis, seismic coefficient method is used. Two types of models (one with shear wall placed at middle of 4 periphery sides, one with shear wall placed at 4 corners in L shape) have been analyzed. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. N° de réf. du vendeur 9786209495076
Quantité disponible : 1 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -The application of the shear wall system in reinforced concrete (RC) buildings has become widely used to minimize seismic consequences.The present literature focuses on two different models with shear walls at different positions. The article showcases the parametric study in terms of displacement, storey drift, and base shear comparison for different location of shear wall in the building. The results are unique and fruitful for future attention. This paper focuses to see the effect of shear wall location in a multi-storied building. An in-plane building of G+10 (11 storey) structure having base dimension of 24m X 24m with typical floor height of 3.3m is considered. In this present work, a storied building was modeled using software and two different models were studied with different location of shear walls in building frame for critical parameters like displacement and base shear under lateral loading. The analysis has been carried out using the ETABS software and for analysis, seismic coefficient method is used. Two types of models (one with shear wall placed at middle of 4 periphery sides, one with shear wall placed at 4 corners in L shape) have been analyzed.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 72 pp. Englisch. N° de réf. du vendeur 9786209495076
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering. N° de réf. du vendeur 9786209495076
Quantité disponible : 1 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. SEISMIC ANALYSIS OF SHEAR WALLS IN BUILDING | Fray Jasson Sayumwe (u. a.) | Taschenbuch | Englisch | 2026 | LAP LAMBERT Academic Publishing | EAN 9786209495076 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu. N° de réf. du vendeur 134537731
Quantité disponible : 5 disponible(s)