This book focuses on examining the influence of wind velocity and angle of attack (AOA) on the maximum permissible input heat flux in a solar-assisted thermoelectric generator (TEG) system. Particular attention has been given to maintaining the allowable hot-side temperature of the thermoelectric module at 150 °C during operation. For effective thermal management, a heat sink configuration consisting of twelve cylindrical fins of 100 mm length has been considered. A three-dimensional Computational Fluid Dynamics (CFD) model has been developed using ANSYS Fluent to simulate the thermal and fluid flow behavior of the system. The numerical model has been validated using available experimental results reported in earlier studies. In the simulation setup, four thermoelectric modules are placed between a heated target plate and a finned cooling block within a low-speed wind tunnel environment. The airflow inside the tunnel represents natural wind conditions, while concentrated solar radiation is applied to the target surface through a Fresnel lens arrangement.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : PBShop.store US, Wood Dale, IL, Etats-Unis
PAP. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur L2-9786630067781
Quantité disponible : Plus de 20 disponibles
Vendeur : Grand Eagle Retail, Bensenville, IL, Etats-Unis
Paperback. Etat : new. Paperback. This book focuses on examining the influence of wind velocity and angle of attack (AOA) on the maximum permissible input heat flux in a solar-assisted thermoelectric generator (TEG) system. Particular attention has been given to maintaining the allowable hot-side temperature of the thermoelectric module at 150 0C during operation. For effective thermal management, a heat sink configuration consisting of twelve cylindrical fins of 100 mm length has been considered. A three-dimensional Computational Fluid Dynamics (CFD) model has been developed using ANSYS Fluent to simulate the thermal and fluid flow behavior of the system. The numerical model has been validated using available experimental results reported in earlier studies. In the simulation setup, four thermoelectric modules are placed between a heated target plate and a finned cooling block within a low-speed wind tunnel environment. The airflow inside the tunnel represents natural wind conditions, while concentrated solar radiation is applied to the target surface through a Fresnel lens arrangement. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability. N° de réf. du vendeur 9786630067781
Quantité disponible : 1 disponible(s)
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. N° de réf. du vendeur I-9786630067781
Quantité disponible : Plus de 20 disponibles
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur L2-9786630067781
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 144 pp. Englisch. N° de réf. du vendeur 9786630067781
Quantité disponible : 2 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. SOLAR THERMOELECTRIC GENERATORS: | HEAT FLUX LIMITATION AND THERMAL PERFORMANCE ANALYSIS | Prateek Debadarsi Roul (u. a.) | Taschenbuch | Englisch | 2026 | LAP LAMBERT Academic Publishing | EAN 9786630067781 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand. N° de réf. du vendeur 135816259
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware 144 pp. Englisch. N° de réf. du vendeur 9786630067781
Quantité disponible : 1 disponible(s)
Vendeur : CitiRetail, Stevenage, Royaume-Uni
Paperback. Etat : new. Paperback. This book focuses on examining the influence of wind velocity and angle of attack (AOA) on the maximum permissible input heat flux in a solar-assisted thermoelectric generator (TEG) system. Particular attention has been given to maintaining the allowable hot-side temperature of the thermoelectric module at 150 0C during operation. For effective thermal management, a heat sink configuration consisting of twelve cylindrical fins of 100 mm length has been considered. A three-dimensional Computational Fluid Dynamics (CFD) model has been developed using ANSYS Fluent to simulate the thermal and fluid flow behavior of the system. The numerical model has been validated using available experimental results reported in earlier studies. In the simulation setup, four thermoelectric modules are placed between a heated target plate and a finned cooling block within a low-speed wind tunnel environment. The airflow inside the tunnel represents natural wind conditions, while concentrated solar radiation is applied to the target surface through a Fresnel lens arrangement. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. N° de réf. du vendeur 9786630067781
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book focuses on examining the influence of wind velocity and angle of attack (AOA) on the maximum permissible input heat flux in a solar-assisted thermoelectric generator (TEG) system. Particular attention has been given to maintaining the allowable hot-side temperature of the thermoelectric module at 150 °C during operation. For effective thermal management, a heat sink configuration consisting of twelve cylindrical fins of 100 mm length has been considered. A three-dimensional Computational Fluid Dynamics (CFD) model has been developed using ANSYS Fluent to simulate the thermal and fluid flow behavior of the system. The numerical model has been validated using available experimental results reported in earlier studies. In the simulation setup, four thermoelectric modules are placed between a heated target plate and a finned cooling block within a low-speed wind tunnel environment. The airflow inside the tunnel represents natural wind conditions, while concentrated solar radiation is applied to the target surface through a Fresnel lens arrangement. N° de réf. du vendeur 9786630067781
Quantité disponible : 2 disponible(s)