System protection is laid between the defenses for power system protective relaying and the emergency control. Under the premise of ensuring the safety of electrical equipment, it strives to ensure the safety of the system, block the chain of occurrence and growth of cascading faults, and effectively avoid the occurrence of large-scale blackout catastrophes. This book systematically elaborates on the dealing technology of a special type of fault, the “cascading fault”, in the AC-DC hybrid large-scale power grid. The main contents include immunization distance protection for accident overload; distance protection that is immune to oscillation; inverter control technology to prevent long-term or continuous commutation failure; DC participation emergency power flow control technology used to share the accident transfer overload caused by inverter lockout; and overhead transmission line adaptive overload protection.The basis of English translation of this book from its Chinese original manuscript was done with the help of artificial intelligence (machine translation by the service provider DeepL.com). A subsequent human revision of the content was done by the author.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Xinzhou Dong is a Professor of Tsinghua University, the head of Power System Protection Research team, the director of the Electric Power Systems Research Institute, Department of Electrical Engineering, Tsinghua University, and the director of Beijing International Science and Technology Cooperation Base for Green Energy and Power Safety. Prof. Dong was born in Shaanxi, China, in 1963. He received the B.Sc., M.Sc., and Ph.D. degrees in Electrical Engineering from Xi'an Jiaotong University, Xi'an, China, in 1983, 1991, and 1996, respectively. He continued his Postdoctoral Research with the Electrical Engineering Station, Tianjin University, Tianjin, China, from 1997 to 1998. Since 1999, he has been with Tsinghua University, Beijing, China. Prof. Dong is an elected IEEE Fellow, IET Fellow, and CSEE Fellow. He serves as the Chairman of IEEE PES Protection and Control technical committee, China, Trustee of CES, Member of the technical committee of CIGRE/CIRED China, Convener of Cigre B5 WG55, Convener of IEC TC95 AGH4, Member of IEEE PSRC Fellow WG. He is a visiting professor of the University of Strathclyde, UK, Chief international professor of National Taipei University of Technology, Talents Program of Shaanxi Province, and Distinguished Professor of the Shaanxi University of Technology. He is also an expert with the special allowance from the State Council of China.His major research areas are as follows, traveling waves-based protection, travelling waves-based-fault location, traveling waves-based-fault line selection, non-communication protection, UHV transmission line's protection, intelligent substation, system protection, and application research on wavelet transform.
Prof. Dong undertook the State Key R&D Plan Project, finished the Major International Collaborative Project of NSFC (National Natural Science Foundation), the Key Project of NSFC, Tsinghua-ALSTOM Research Center on Protection and Control etc..Prof. Dong has publishedover 400 papers, 7 books with co-authors. He holds 25 international patents, 77 Chinese patents. He has received numerous awards from the government and the societies, including the 2020 Chinese National Innovation Award, State Technological Invention Award of the Chinese government (2nd Prize) respectively in 2017 and 2007, 4 Science and Technology Award from Beijing government or CSEE(all 1st Prize). Since 2017 he was named the Chinese Highly Cited Researcher by Elsevier.
Les informations fournies dans la section « A propos du livre » peuvent faire référence à une autre édition de ce titre.
Vendeur : Brook Bookstore On Demand, Napoli, NA, Italie
Etat : new. Questo è un articolo print on demand. N° de réf. du vendeur AVLCTKDVCS
Quantité disponible : Plus de 20 disponibles
Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 344 pp. Englisch. N° de réf. du vendeur 9789811964886
Quantité disponible : 2 disponible(s)
Vendeur : Ria Christie Collections, Uxbridge, Royaume-Uni
Etat : New. In. N° de réf. du vendeur ria9789811964886_new
Quantité disponible : Plus de 20 disponibles
Vendeur : moluna, Greven, Allemagne
Etat : New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. System protection is laid between the defenses for power system protective relaying and the emergency control. Under the premise of ensuring the safety of electrical equipment, it strives to ensure the safety of the system, block the chain of occurrence and. N° de réf. du vendeur 1128556514
Quantité disponible : Plus de 20 disponibles
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. Druck auf Anfrage Neuware - Printed after ordering. N° de réf. du vendeur 9789811964886
Quantité disponible : 1 disponible(s)
Vendeur : Revaluation Books, Exeter, Royaume-Uni
Paperback. Etat : Brand New. 341 pages. 9.25x6.10x0.72 inches. In Stock. N° de réf. du vendeur x-9811964882
Quantité disponible : 2 disponible(s)
Vendeur : preigu, Osnabrück, Allemagne
Taschenbuch. Etat : Neu. AC/DC Hybrid Large-Scale Power Grid System Protection | Xinzhou Dong | Taschenbuch | xvii | Englisch | 2023 | Springer | EAN 9789811964886 | Verantwortliche Person für die EU: Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg, juergen[dot]hartmann[at]springer[dot]com | Anbieter: preigu. N° de réf. du vendeur 127727153
Quantité disponible : 5 disponible(s)
Vendeur : buchversandmimpf2000, Emtmannsberg, BAYE, Allemagne
Taschenbuch. Etat : Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book systematically elaborates on the dealing technology of a special type of fault, the 'cascading fault', in the AC-DC hybrid large-scale power grid. The main contents include immunization distance protection for accident overload; distance protection that is immune to oscillation; inverter control technology to prevent long-term or continuous commutation failure; DC participation emergency power flow control technology used to share the accident transfer overload caused by inverter lockout; and overhead transmission line adaptive overload protection.Springer-Verlag KG, Sachsenplatz 4-6, 1201 Wien 344 pp. Englisch. N° de réf. du vendeur 9789811964886
Quantité disponible : 1 disponible(s)