This handbook closes that gap in a single volume. It establishes the thermodynamic foundations, develops the vapour-compression cycle from its four processes, then follows the refrigerant through each component in the order it actually meets them — and finishes in the field, with evacuation, charging, diagnosis, and compliance.
Coverage runs across sixteen chapters and five appendices: refrigerant properties and safety classification, compressors and capacity control, condensers and heat rejection, evaporators and metering devices, line sizing and accessories, psychrometrics, load estimation, duct and hydronic distribution, air handling selection, heat pumps, heat recovery, transcritical carbon dioxide, absorption and cascade systems, controls and automation, and commissioning and service.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : PBShop.store UK, Fairford, GLOS, Royaume-Uni
PAP. Etat : New. New Book. Shipped from UK. Established seller since 2000. N° de réf. du vendeur L2-9798170287116
Quantité disponible : Plus de 20 disponibles
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. Print on Demand. N° de réf. du vendeur I-9798170287116
Quantité disponible : Plus de 20 disponibles
Vendeur : Grand Eagle Retail, Bensenville, IL, Etats-Unis
Paperback. Etat : new. Paperback. A system that will not cool is rarely a mystery. It is a question about where the heat is going - and the fastest technicians are the ones who know how to ask it.Refrigeration and air conditioning work punishes memorised answers. A service technician who has learned a symptom table can match gauge readings to a probable cause until the night the system does not match any row in that table. A design engineer can defend a catalogue selection until someone asks why. A student handed a formula without its derivation can pass an examination and still be unable to reason about a machine behaving unexpectedly. The gap is not a shortage of information. It is the missing link between the physics and the practice.This handbook closes that gap in a single volume. It establishes the thermodynamic foundations, develops the vapour-compression cycle from its four processes, then follows the refrigerant through each component in the order it actually meets them - and finishes in the field, with evacuation, charging, diagnosis, and compliance.What this handbook helps you do: Read a pressure and enthalpy diagram and compute refrigerating effect, compressor work, heat rejection, coefficient of performance, and mass flowTreat superheat and subcooling as descriptions of state, and recognise what a departure suggests about charge, airflow, metering, or heat rejectionEstimate heating and cooling loads from transmission, infiltration, ventilation, solar gain, and internal gains, and see why a heat gain is not a cooling loadSize ducts and refrigerant lines, read a fan curve, apply the fan laws, and recognise system effect before it becomes a complaintWork through psychrometric processes - mixing, sensible cooling, dehumidification, reheat - with the relationships that govern themFollow a structured diagnostic pattern from measurement to fault signature instead of exchanging parts and hopingUnderstand what the low global warming potential refrigerant transition asks of charge limits, service practice, and recordsCoverage runs across sixteen chapters and five appendices: refrigerant properties and safety classification, compressors and capacity control, condensers and heat rejection, evaporators and metering devices, line sizing and accessories, psychrometrics, load estimation, duct and hydronic distribution, air handling selection, heat pumps, heat recovery, transcritical carbon dioxide, absorption and cascade systems, controls and automation, and commissioning and service.Every equation defines its variables and units. Worked examples show each material step. Practice problems are graded and every answer appears in the answer key. Units are United States customary with SI equivalents throughout.Written for service technicians, refrigeration and air conditioning contractors, mechanical and building services engineers, facilities and maintenance staff, apprentices, and students.Open it at the chapter you need tonight, and begin reasoning about systems instead of memorising them. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability. N° de réf. du vendeur 9798170287116
Quantité disponible : 1 disponible(s)
Vendeur : CitiRetail, Stevenage, Royaume-Uni
Paperback. Etat : new. Paperback. A system that will not cool is rarely a mystery. It is a question about where the heat is going - and the fastest technicians are the ones who know how to ask it.Refrigeration and air conditioning work punishes memorised answers. A service technician who has learned a symptom table can match gauge readings to a probable cause until the night the system does not match any row in that table. A design engineer can defend a catalogue selection until someone asks why. A student handed a formula without its derivation can pass an examination and still be unable to reason about a machine behaving unexpectedly. The gap is not a shortage of information. It is the missing link between the physics and the practice.This handbook closes that gap in a single volume. It establishes the thermodynamic foundations, develops the vapour-compression cycle from its four processes, then follows the refrigerant through each component in the order it actually meets them - and finishes in the field, with evacuation, charging, diagnosis, and compliance.What this handbook helps you do: Read a pressure and enthalpy diagram and compute refrigerating effect, compressor work, heat rejection, coefficient of performance, and mass flowTreat superheat and subcooling as descriptions of state, and recognise what a departure suggests about charge, airflow, metering, or heat rejectionEstimate heating and cooling loads from transmission, infiltration, ventilation, solar gain, and internal gains, and see why a heat gain is not a cooling loadSize ducts and refrigerant lines, read a fan curve, apply the fan laws, and recognise system effect before it becomes a complaintWork through psychrometric processes - mixing, sensible cooling, dehumidification, reheat - with the relationships that govern themFollow a structured diagnostic pattern from measurement to fault signature instead of exchanging parts and hopingUnderstand what the low global warming potential refrigerant transition asks of charge limits, service practice, and recordsCoverage runs across sixteen chapters and five appendices: refrigerant properties and safety classification, compressors and capacity control, condensers and heat rejection, evaporators and metering devices, line sizing and accessories, psychrometrics, load estimation, duct and hydronic distribution, air handling selection, heat pumps, heat recovery, transcritical carbon dioxide, absorption and cascade systems, controls and automation, and commissioning and service.Every equation defines its variables and units. Worked examples show each material step. Practice problems are graded and every answer appears in the answer key. Units are United States customary with SI equivalents throughout.Written for service technicians, refrigeration and air conditioning contractors, mechanical and building services engineers, facilities and maintenance staff, apprentices, and students.Open it at the chapter you need tonight, and begin reasoning about systems instead of memorising them. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. N° de réf. du vendeur 9798170287116
Quantité disponible : 1 disponible(s)
Vendeur : AHA-BUCH GmbH, Einbeck, Allemagne
Taschenbuch. Etat : Neu. Neuware. N° de réf. du vendeur 9798170287116
Quantité disponible : 2 disponible(s)