This reference builds radiographic positioning technique on the physics of x-ray production, exposure formation, and equipment operation, then carries that foundation through every body region, contrast and fluoroscopic study, cross-sectional modality, and special patient population a radiologic technology student or working radiographer will encounter. Sixty-four Image Verification System entries — one paired positioning-and-rejection standard for nearly every major projection in the book — replace vague positioning advice with a defined, checkable criterion for accepting or repeating an image. The result moves the reader from anode heel effect compensation and tube-loading calculations to the bedside judgment that decides whether a cross-table cervical spine or a bariatric abdominal film actually answers the clinical question.
A dedicated Verification Atlas indexes every criterion by anatomic region and by rejection cause — rotation, exposure, timing, incomplete coverage — for fast lookup during a shift.
From the Console to the Reading Room, You Will
• Diagnose exposure and equipment problems — distinguish a centering error from a positioning error, apply the anode heel effect deliberately, and verify tube loading before a high-technique exposure.
• Verify every major projection before releasing the patient — orthogonal criteria for the hand through the skull, embedded in a five-part Image Verification System used in every chapter.
• Confirm chest and abdomen studies are complete — the three-criterion PA chest check, full KUB coverage, and free-air detection on an upright chest.
• Run contrast, fluoroscopic, mobile, and surgical studies — duodenal bulb filling timing, nephrogram phase accuracy, and sterile-field C-arm verification.
• Extend the same discipline into CT, MRI, ultrasound, nuclear medicine, and mammography — isocenter centering, contrast phase timing, and MRI safety screening.
• Adapt technique for pediatric, geriatric, bariatric, and trauma patients — growth-plate recognition, kyphosis-adapted positioning, and cross-table cervical spine imaging for the patient who cannot be moved.
• Manage radiation safety and departmental quality — dosimetry verification, ALARA-driven decisions, informed consent documentation, and repeat/reject analysis that closes the loop.
Put this reference beside every console you work — for the patients who deserve a diagnostic image the first time.
Les informations fournies dans la section « Synopsis » peuvent faire référence à une autre édition de ce titre.
Vendeur : California Books, Miami, FL, Etats-Unis
Etat : New. Print on Demand. N° de réf. du vendeur I-9798194571079
Quantité disponible : Plus de 20 disponibles