Impression Material: Monophasic Polyvinyl Siloxane | Dimensional Accuracy in Different Tray Spaces & Repeat Pours. Cet article n’est pas disponible.
Langue : anglais
Edité par LAP Lambert Academic Publishing, 2012
- Livre broché
- Neuf

Vendeur : preigu, Osnabrück, Allemagnepreigu
Vendeur avec une évaluation de 5 étoiles
Vendeur AbeBooks depuis 5 août 2024
Indisponible
Livre broché
Etat: Neuf
EUR 43,40
Item description from seller
Impression Material: Monophasic Polyvinyl Siloxane | Dimensional Accuracy in Different Tray Spaces & Repeat Pours | Sandeep Kumar (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9783844358056 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.
N° de réf. du vendeur 106244755
- Titre
- Impression Material: Monophasic Polyvinyl Siloxane | Dimensional Accuracy in Different Tray Spaces & Repeat Pours
- Auteur
- Sandeep Kumar (u. a.)
- Éditeur
- LAP Lambert Academic Publishing
- Année de publication
- 2012
- État de l'article
- Neu
- Reliure
- Taschenbuch
- Langue
- anglais
- ISBN à 10 chiffres
- 3844358056
- ISBN à 13 chiffres
- 9783844358056
- Catalogues du vendeur
- Bücher
Clinical success of fixed prosthodontic procedures is dependent in part upon the dimensional accuracy of elastomeric impression materials and impression procedures. The variable thickness of the impression material in tray may result in dimensional change & inaccuracies in the cast. There is distortion of the impression material during retrieval of stone casts, when multiple casts are poured in the same impression. This book is directed towards the effect of various tray spaces (2mm, 4mm and 6mm) and subsequent repeated pours (2 times) on the accuracy of monophasic polyvinyl siloxane impression material. It was found that the vertical distance of stone dies decreased, whereas horizontal distance increased as the thickness of impression material is increased. There were statistically non significant changes occurring among the repeated pours in 2mm, 4mm and 6mm spaced custom trays.
« Synopsis » peut appartenir à une autre édition de cet ouvrage.
Présentation de l'éditeur
Clinical success of fixed prosthodontic procedures is dependent in part upon the dimensional accuracy of elastomeric impression materials and impression procedures. The variable thickness of the impression material in tray may result in dimensional change & inaccuracies in the cast. There is distortion of the impression material during retrieval of stone casts, when multiple casts are poured in the same impression. This book is directed towards the effect of various tray spaces (2mm, 4mm and 6mm) and subsequent repeated pours (2 times) on the accuracy of monophasic polyvinyl siloxane impression material. It was found that the vertical distance of stone dies decreased, whereas horizontal distance increased as the thickness of impression material is increased. There were statistically non significant changes occurring among the repeated pours in 2mm, 4mm and 6mm spaced custom trays.
« A propos de ce titre » peut appartenir à une autre édition de cet ouvrage.