National Building Standard Design Atlas (12SDX101-2): civil electrical design calculations and examples(Chinese Edition)
- Livre broché
- Neuf

Vendeur : liu xing, Nanjing, JS, Chineliu xing
Vendeur AbeBooks depuis 7 avril 2009
Etat: Neuf
EUR 97,49
- Paypal
- Virement bancaire
Quantité disponible : 1 disponible
Ajouter au panierVous souhaitez payer avec votre carte de crédit ?
A propos de cet article
Ship out in 2 business day, And Fast shipping, Free Tracking number will be provided after the shipment.Paperback. Pub Date: 2012 07 Pages: 118 Language: Chinese in Publisher: China plans to Press 12SDX101-2 civil electrical design and calculation examples According to the current national standards and engineering design to actual needs. the preparation of civil electrical commonly used in the design calculations and examples for designers to use and reference. National Building Standard Design Atlas (12SDX101-2): civil electrical design calculations and examples include: supply and distribution system. the choice of short circuit current calculation with high and low voltage electrical relay protection calculation. wire and cable section selection and calculation of electrical lighting calculations. building lightning protection and grounding calculation. the weak systems used in the calculation of the engineering example. National Building Standard Design Atlas (12SDX101-2): civil electrical design calculations and examples by calculating principle calculation method. specification requirements and examples used in the process of building electrical design calculation introduced in order to design were able to correct depth understanding and mastery of building electrical design calculation methods and related regulatory requirements. Contents: cataloging a substation load calculation device power computational load to determine single-phase load peak current reactive power compensation capacity of the transformer power supply system power loss calculation of the power supply system power loss calculation and annual electricity consumption selection of high-voltage electrical calculation diesel generator capacity of UPS and EPS installed capacity of solar photovoltaic power system capacity harmonic calculation 2 short-circuit current is calculated with high and low voltage select high and low voltage electrical system short-circuit current is calculated short-circuit current of the power supply system of the diesel generator neutral point grounding device selection current transformer selection voltage transformer low-voltage electrical power transformer protection relay protection power capacitors for high-voltage power lines to protect high-voltage motor protection high voltage bus segment circuit breaker protection for the distribution system microcomputer protection design 4 wire and cable cross-section to select the selection criteria of the wire and cable cross-section to select the economic cross-section by economic current density allowable temperature rise selective cross voltage loss checksum-section by a short circuit heat stable condition check the cross-section and low voltage distribution system neutral line line of protection and protection of the cross-section of the neutral line hard busbar cross-section select 5 commonly used in electrical equipment. motor elevator 6 electrical lighting the illumination calculation estimates of the utilization factor method curve method illuminance calculated point by point calculation method the illuminance calculation 7 Building Lightning Protection calculate building expected camera lens used in the calculation of the number of lightning strikes the scope of protection lightning rod grounding resistance calculation weak project selection DVR capacity to select the video coaxial effective transmission distance calculated the calculated PA system broadcast system amplifier capacity feeder impedance matching. voltage matching calculation wired the related calculations estimate the number of cable socket estimate the number of fiber optic attenuation engine room. TV system user assigned Telecom equipment room area calculation the integrated wiring device configuration Example 9 engineering sample project overview and electrical equipment load to calculate electrical equipment load calculating transformer selection of their own emergency power supply capacity calculation of.…
N° de réf. du vendeur NE048645
Détails bibliographiques
- Titre
- National Building Standard Design Atlas (12SDX101-2): civil electrical design calculations and examples(Chinese Edition)
- Auteur
- ZHONG GUO JIAN ZHU BIAO ZHUN SHE JI YAN JIU YUAN
- État de l'article
- New
- Reliure
- paperback
- ISBN à 10 chiffres
- 7802427800
- ISBN à 13 chiffres
- 9787802427808
liu xing
Nanjing, JS, Chine
Vendeur AbeBooks depuis 7 avril 2009
Frais d'expédition de Chine vers Etats-Unis
| Article | 16 à 30 jours ouvrés | 8 à 16 jours ouvrés |
|---|---|---|
| Premier article | EUR 16,00 | EUR 26,66 |
Description de la boutique
Thank you for visiting My bookstore! We are an online bookstore, and Is the China's largest online book sales. Generally our books are from China, with reasonable price and decent printing quality. We are always trying our best to satisfy customer's needs!
Spécialité
Chemistry, Mathematics, Computer, Physics, Environment, Social SciencesProfil professionnel du vendeur
NAN JING SHI JIANG NING QU NING YUAN DIAN ZI SHANG WU ZHONG XIN
Room 264, Oujiang Shopping Center, No. 1 Dongxin South Road, Dongshan Street, Jiangning District, NanJing
Nanjing, JS Chine 211100
Conditions de vente
We guarantee the condition of every book as it's described on the Abebooks web sites. If you're dissatisfied with your purchase (Incorrect Book/Not as Described/Damaged) or if the order hasn't arrived, you're eligible for a refund within 30 days of the estimated delivery date. If you've changed your mind about a book that you've ordered, please use the Ask bookseller a question link to contact us and we'll respond within 2 business days. Please Note:We don't sell any international Edition to you. Don't send any question about international Edition to us.
Droit de rétractation
Si vous êtes un consommateur, vous pouvez exercer votre droit de rétractation sur le contrat conformément à ce qui suit. Le mot « consommateur » désigne toute personne physique agissant à des fins qui n'entrent pas dans le cadre de son activité commerciale, artisanale ou professionnelle.
Informations concernant le droit de rétractation
Droit statutaire de rétractation
Vous avez le droit d'exercer votre droit de rétractation sur ce contrat dans les 14 jours sans donner de raison.
Le délai de rétractation expirera au bout de 14 jours à compter du jour où vous-même, ou un tiers autre que le transporteur et désigné par vous, prendrez physiquement possession de la dernière marchandise, du dernier lot ou de la dernière pièce.
Pour exercer votre droit de rétractation, remplissez électroniquement et envoyez une déclaration claire sur notre site Web, sous « Vos achats » dans « Votre compte ». Nous vous communiquerons sans délai un accusé de réception de cette rétractation sur un support durable (par exemple, par e-mail).
Pour respecter le délai de rétractation, il vous suffit d'envoyer votre message concernant l'exercice de votre droit de rétractation avant l'expiration du délai de rétractation.
Effets de la rétractation
Si vous exercez votre droit de rétractation sur ce contrat, nous vous rembourserons tous les paiements que vous avez effectués, y compris les frais de livraison (à l'exception des frais supplémentaires résultant du choix d'un mode de livraison autre que le type de livraison standard le moins cher que nous proposons).
Nous pouvons déduire du remboursement la perte de valeur de toute marchandise livrée, si la perte est le résultat d'une manipulation inutile de votre part.
Nous effectuerons le remboursement dans les meilleurs délais, et au plus tard 14 jours après le jour où nous aurons été informés de votre décision d'exercer votre droit de rétractation sur ce contrat.
Nous effectuerons le remboursement en utilisant le même moyen de paiement que celui que vous avez utilisé pour la transaction initiale, sauf si vous en avez expressément convenu autrement ; en tout état de cause, aucuns frais ne vous seront facturés à la suite d'un tel remboursement.
Nous pouvons suspendre le remboursement jusqu'à ce que nous ayons reçu les marchandises ou que vous ayez fourni la preuve que vous avez renvoyé les marchandises, en fonction de la première éventualité.
Vous devez renvoyer les marchandises ou les remettre à liu xing, Nanjing, JS, China, sans retard injustifié et, en tout état de cause, au plus tard 14 jours à compter du jour où vous nous avez communiqué votre décision de rétractation du présent contrat. Le délai est respecté si vous renvoyez les marchandises avant l'expiration du délai de 14 jours. Vous devrez prendre en charge les frais directs du renvoi des marchandises. Vous n'êtes responsable que de toute diminution de valeur des marchandises résultant d'une manipulation autre que celle nécessaire pour établir la nature, les caractéristiques et le fonctionnement des marchandises.
Exceptions au droit de rétractation
Le droit de rétractation ne s'applique pas à ce qui suit :
- Distribution de journaux, de revues ou de magazines, à l'exception des contrats d'abonnement ; et
- Fourniture d'un contenu numérique qui n'est pas fourni sur un support matériel (par exemple, sur un CD ou un DVD) si vous avez accepté, lors de votre commande, que nous puissions commencer à le livrer et que vous ne puissiez pas exercer votre droit de rétractation une fois la livraison commencée.
Conditions d'expédition
Most orders are shipped within 24 hours. We will delivery these items to you by SAL, EUB, EMS, FEDEX etc.