Refrigeration and Air Conditioning Handbook (Paperback)
Langue : anglais
Edité par Independently Published, 2026
- Livre broché
- Neuf

Vendeur : Grand Eagle Retail, Bensenville, IL, Etats-UnisGrand Eagle Retail
Vendeur AbeBooks depuis 12 octobre 2005
Etat: Neuf
EUR 117,13
Quantité disponible : 1 disponible(s)
Ajouter au panierItem description from seller
Paperback. For most of the twentieth century a technician could learn one refrigerant, learn the pressures that went with it, and carry that knowledge for a working lifetime. That is no longer possible.The chlorinated fluids were withdrawn. The high global warming potential fluids that replaced them are being withdrawn in turn, and the fluids taking their place are mildly flammable. A cylinder on a truck today may hold a blend of five components with a temperature glide that punishes anyone who charges it as vapour. A rooftop unit installed this year is likely to carry a refrigerant that did not exist commercially when the technician servicing it began an apprenticeship.Meanwhile the same technician is asked to charge a residential split system, diagnose a communicating control, and work out why a walk-in freezer will not pull down. Procedure-only training fails here, because a procedure works on the system it was written for and a mechanism works on all of them.This handbook is built on that division. The physics comes first and is treated as permanent. The fluids, the regulations and the equipment come second, and are treated as things to verify rather than memorise; where a rule is likely to change, the principle behind it is given alongside the rule.What you will take from itThe ability to read a system from two gauges and two thermometers whatever fluid is inside it, including glide, dew point and bubble point, and why superheat is read against one column and subcooling against the other.A diagnostic order that does not change - listen, look, electrical, airflow, refrigerant, confirm - and the reason airflow must be measured before any refrigerant reading is interpreted.The superheat and subcooling grid that places a fault on one side of the metering device, and the pressure patterns that separate a compressor fault from an air-side fault.Airflow measured properly by traverse, flow hood, anemometer, blower table or temperature rise, with external static pressure partitioned among filter, coil, return and supply.Electrical method: voltage in parallel with power on, current clamped around one conductor, resistance on an isolated device with power off - and always the question of what destroyed the component you are replacing.Installation that does not fail later: nitrogen flowing through every brazed joint, a dry-nitrogen pressure test, evacuation to five hundred microns proved by a decay test, and charging by the method the metering device requires.One hundred and sixteen worked examples with every arithmetic step and unit shown, and more than a hundred and forty practice problems answered with the reasoning, not just the result.Fifteen chapters run from heat and the vapour-compression cycle through working fluids, compressors, heat exchangers, metering devices and piping, then psychrometrics, duct design and airflow, electrical fundamentals and controls, heat pumps, and commercial and industrial refrigeration, closing with installation practice and systematic fault diagnosis. Three appendices give saturation and glide tables, every numbered equation in one place, and a field quick reference of target values, pressure patterns, electrical checks and safety rules. A glossary of roughly one hundred and ninety terms and a full index complete it, with units given in both systems throughout.It is written for the working technician sent from one generation of equipment to another, the installer whose callbacks begin at commissioning, the apprentice learning the reasons behind the steps, and the trade-school or two-year student with an examination to pass and a first year in the field to survive.Open it at the first chapter and start building the understanding that outl Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…
N° de réf. du vendeur 9798170304998
- Titre
- Refrigeration and Air Conditioning Handbook (Paperback)
- Auteur
- Ridgeline Engineering Press
- Éditeur
- Independently Published
- Année de publication
- 2026
- État de l'article
- new
- Reliure
- Paperback
- Langue
- anglais
- ISBN à 13 chiffres
- 9798170304998
For most of the twentieth century a technician could learn one refrigerant, learn the pressures that went with it, and carry that knowledge for a working lifetime. That is no longer possible.
The chlorinated fluids were withdrawn. The high global warming potential fluids that replaced them are being withdrawn in turn, and the fluids taking their place are mildly flammable. A cylinder on a truck today may hold a blend of five components with a temperature glide that punishes anyone who charges it as vapour. A rooftop unit installed this year is likely to carry a refrigerant that did not exist commercially when the technician servicing it began an apprenticeship.
Meanwhile the same technician is asked to charge a residential split system, diagnose a communicating control, and work out why a walk-in freezer will not pull down. Procedure-only training fails here, because a procedure works on the system it was written for and a mechanism works on all of them.
This handbook is built on that division. The physics comes first and is treated as permanent. The fluids, the regulations and the equipment come second, and are treated as things to verify rather than memorise; where a rule is likely to change, the principle behind it is given alongside the rule.
What you will take from it
- The ability to read a system from two gauges and two thermometers whatever fluid is inside it, including glide, dew point and bubble point, and why superheat is read against one column and subcooling against the other.
- A diagnostic order that does not change - listen, look, electrical, airflow, refrigerant, confirm - and the reason airflow must be measured before any refrigerant reading is interpreted.
- The superheat and subcooling grid that places a fault on one side of the metering device, and the pressure patterns that separate a compressor fault from an air-side fault.
- Airflow measured properly by traverse, flow hood, anemometer, blower table or temperature rise, with external static pressure partitioned among filter, coil, return and supply.
- Electrical method: voltage in parallel with power on, current clamped around one conductor, resistance on an isolated device with power off - and always the question of what destroyed the component you are replacing.
- Installation that does not fail later: nitrogen flowing through every brazed joint, a dry-nitrogen pressure test, evacuation to five hundred microns proved by a decay test, and charging by the method the metering device requires.
- One hundred and sixteen worked examples with every arithmetic step and unit shown, and more than a hundred and forty practice problems answered with the reasoning, not just the result.
Fifteen chapters run from heat and the vapour-compression cycle through working fluids, compressors, heat exchangers, metering devices and piping, then psychrometrics, duct design and airflow, electrical fundamentals and controls, heat pumps, and commercial and industrial refrigeration, closing with installation practice and systematic fault diagnosis. Three appendices give saturation and glide tables, every numbered equation in one place, and a field quick reference of target values, pressure patterns, electrical checks and safety rules. A glossary of roughly one hundred and ninety terms and a full index complete it, with units given in both systems throughout.
It is written for the working technician sent from one generation of equipment to another, the installer whose callbacks begin at commissioning, the apprentice learning the reasons behind the steps, and the trade-school or two-year student with an examination to pass and a first year in the field to survive.
Open it at the first chapter and start building the understanding that outlasts the fluid in the cylinder.
Click the "Buy Now" button to purchase.
« Synopsis » peut appartenir à une autre édition de cet ouvrage.
Grand Eagle Retail
Bensenville, IL, Etats-Unis
Vendeur AbeBooks depuis 12 octobre 2005
Frais d'expédition à l'intérieur de ce pays : Etats-Unis
| Article | 6 à 14 jours ouvrés | 6 à 16 jours ouvrés |
|---|---|---|
| Premier article | EUR 0,00 | EUR 0,00 |
Modes de paiement
Profil professionnel du vendeur
APOLLO ONLINE CORP.
605 Geddes Street
Wilmington, DE Etats-Unis 19805
Conditions de vente
We guarantee the condition of every book as it¿s described on the Abebooks web sites. If you¿ve changed
your mind about a book that you¿ve ordered, please use the Ask bookseller a question link to contact us
and we¿ll respond within 2 business days.
Books ship from California and Michigan.
Droit de rétractation
Si vous êtes un consommateur, vous pouvez exercer votre droit de rétractation sur le contrat conformément à ce qui suit. Le mot « consommateur » désigne toute personne physique agissant à des fins qui n'entrent pas dans le cadre de son activité commerciale, artisanale ou professionnelle.
Informations concernant le droit de rétractation
Droit statutaire de rétractation
Vous avez le droit d'exercer votre droit de rétractation sur ce contrat dans les 14 jours sans donner de raison.
Le délai de rétractation expirera au bout de 14 jours à compter du jour où vous-même, ou un tiers autre que le transporteur et désigné par vous, prendrez physiquement possession de la dernière marchandise, du dernier lot ou de la dernière pièce.
Pour exercer votre droit de rétractation, remplissez électroniquement et envoyez une déclaration claire sur notre site Web, sous « Vos achats » dans « Votre compte ». Nous vous communiquerons sans délai un accusé de réception de cette rétractation sur un support durable (par exemple, par e-mail).
Pour respecter le délai de rétractation, il vous suffit d'envoyer votre message concernant l'exercice de votre droit de rétractation avant l'expiration du délai de rétractation.
Effets de la rétractation
Si vous exercez votre droit de rétractation sur ce contrat, nous vous rembourserons tous les paiements que vous avez effectués, y compris les frais de livraison (à l'exception des frais supplémentaires résultant du choix d'un mode de livraison autre que le type de livraison standard le moins cher que nous proposons).
Nous pouvons déduire du remboursement la perte de valeur de toute marchandise livrée, si la perte est le résultat d'une manipulation inutile de votre part.
Nous effectuerons le remboursement dans les meilleurs délais, et au plus tard 14 jours après le jour où nous aurons été informés de votre décision d'exercer votre droit de rétractation sur ce contrat.
Nous effectuerons le remboursement en utilisant le même moyen de paiement que celui que vous avez utilisé pour la transaction initiale, sauf si vous en avez expressément convenu autrement ; en tout état de cause, aucuns frais ne vous seront facturés à la suite d'un tel remboursement.
Nous pouvons suspendre le remboursement jusqu'à ce que nous ayons reçu les marchandises ou que vous ayez fourni la preuve que vous avez renvoyé les marchandises, en fonction de la première éventualité.
Vous devez renvoyer les marchandises ou les remettre à Grand Eagle Retail, Bensenville, Illinois, U.S.A., sans retard injustifié et, en tout état de cause, au plus tard 14 jours à compter du jour où vous nous avez communiqué votre décision de rétractation du présent contrat. Le délai est respecté si vous renvoyez les marchandises avant l'expiration du délai de 14 jours. Vous devrez prendre en charge les frais directs du renvoi des marchandises. Vous n'êtes responsable que de toute diminution de valeur des marchandises résultant d'une manipulation autre que celle nécessaire pour établir la nature, les caractéristiques et le fonctionnement des marchandises.
Exceptions au droit de rétractation
Le droit de rétractation ne s'applique pas à ce qui suit :
- Distribution de journaux, de revues ou de magazines, à l'exception des contrats d'abonnement ; et
- Fourniture d'un contenu numérique qui n'est pas fourni sur un support matériel (par exemple, sur un CD ou un DVD) si vous avez accepté, lors de votre commande, que nous puissions commencer à le livrer et que vous ne puissiez pas exercer votre droit de rétractation une fois la livraison commencée.
Conditions d'expédition
Orders usually ship within 2 business days. All books within the US ship free of charge. Delivery is 4-14 business days anywhere in the United States.
Books ship from California and Michigan.
If your book order is heavy or oversized, we may contact you to let you know extra shipping is required.