Systems for Remotely Controlled Decommissioning Operations

Langue : anglais

Edité par Springer Jun 1986, 1986

0860105482 / 9780860105480

Vendeur : BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AllemagneBuchWeltWeit Ludwig Meier e.K.

Vendeur avec une évaluation de 5 étoiles

Vendeur AbeBooks depuis 11 janvier 2012

Livre broché

Etat: Neuf

EUR 106,99

EUR 23,00 expédition 
Expédition depuis Allemagne vers Etats-Unis

Quantité disponible : 1 disponible

Ajouter au panier
Retours gratuits sous 30 jours

A propos de cet article

This item is printed on demand - it takes 3-4 days longer - Neuware -1. Executive Summary.- 1.1. Scope of study.- 1.2. Summary of findings.- 1.2.1. Review of already performed remote-controlled operations in decommissioning.- 1.2.2. Definition of the different tasks in decommissioning and of the techniques which may possibly be applied.- 1.2.3. State of the art of existing equipment as applicable for decommissioning tasks.- 1.2.4. Systems analysis of all tasks suitable for remote handling and specification of corresponding hard-and software.- 1.2.5. Conceptual design of most promising systems.- 1.2.6. Conclusions. Needed developments and recommendations for future works.- 2. Review of Remote Controlled Operations in Decommissioning.- 2.1. Already performed decontamination and dismantling operations.- 2.1.1. Eurochemic.- 2.1.2. Fast reactor reprocessing plant.- 2.1.3. Trino Vercellese PWR reactor.- 2.1.4. Garigliano reactor.- 2.1.5. SRE and ERR reactors.- 2.1.6. Organic moderated reactor experiment.- 2.1.7. Remote handling in the decommissioning of 1ight water reactors and related fields.- 2.2. Plans and schedules for future decommissioning operations 18 and projects for dismantling techniques.- 2.2.1. WAGR.- 2.2.2. TM-2.- 2.2.3. KKN.- 2.2.4. Projects of dismantling machines.- 2.2.5. Plansand studies on future decommissioning projects.- References.- 3. Definition of the Different Tasks In Decommissioning and of the Techniques Which May Be Possibly Be Applied.- 3.1. Synopsis of the tasks occuring in decommissioning of nuclear power plants.- 3.1.1. Decommissioning alternatives.- 3.1.2. Summary of decommissioning tasks.- 3.2. Synopsis of the decommissioning techniques.- 3.2.1. Synopsis of the cutting techniques.- 3.3. Specification tables and technical data on decommissionung techniques.- References.- 4. State of the Art of Remotely Controlled Equipment.- 4.1. Equipment for remote dismantling in the bioshield.- 4.2. General purpose systems.- 4.2.1. Fixed industrial robot systems.- 4.2.2. Mobile robot systems.- 4.2.3. Signal processing and autonomous operation.- 4.3. Sub-systems.- 4.3.1. Vision sub-systems.- 4.3.2. Sensors and automatic positioning.- 4.3.3. Special manipulators.- References.- 5. System Analysis of All Tasks Suited for Remote Control and Specication of the Corresponding Hard-And Software.- 5.1. Task-specific potential.- 5.1.1. Definition of decommissioning operations.- 5.1.2. Plant systems.- 5.2. Type classification of tasks suited for remote control.- 5.2.1. Tasks areas.- 5.2.2. Plant-specific remote-control work.- 5.2.3. Task-specific remote-control work.- 5.3. Model of the dose reduction by robotic systems.- 5.3.1. Approach to the model.- 5.3.2. Analysis of technique-specific manrem savings.- 5.4. Analysis of remote-control work sequences.- 5.4.1. Plant survey and monitoring.- 5.4.2. Segmentation of metallic components.- 5.4.3. Decontamination of buildings structure surface.- 5.5. Definition of the performance profile for remote-controlled systems.- 5.6. Specification of hard-and software systems of remote-controlled equipment.- 5.6.1. Specification of the hard-and software systems.- 5.6.2. Concepts for remote-controlled equipment.- 5.6.3. Structure of a survey and monitoring device.- 5.7. Advanced technologies and subsystems.- 5.7.1. Data transmission via fibre-optic cables.- 5.7.2. Bus system for special vehicles and operation systems.- 5.7.3. Processor and robot system.- References.- 6. Conceptual Design of the Most Promising System.- 6.1. Survey and monitoring system vehicle.- 6.1.1. Basic design features.- 6.1.2. Inspection means.- 6.1.3. Radio-transmission.- 6.1.4. Power supply.- 6.1.5. Vehicle guiding system.- 6.2. Identification of functions common to the most promising systems.- 6.3. Electro-mechanical aspects.- 6.3.1. Power supply.- 6.3.2. Driving mechanisms - propulsion.- 6.3.3. Manipulator kinematics and dynamics.- 6.3.4. Base and stabilization.- 6.4. Environmental aspects.- 6.4.1. General design base.…

Détails bibliographiques

Titre
Systems for Remotely Controlled Decommissioning Operations
Auteur
E. Kirchner
Éditeur
Springer Jun 1986
Année de publication
1986
État de l'article
Neu
Reliure
Taschenbuch
Langue
anglais
ISBN à 10 chiffres
0860105482
ISBN à 13 chiffres
9780860105480
Poids de l'article
654 grammes
Dimensions
297x210x14 mm

BuchWeltWeit Ludwig Meier e.K.

Bergisch Gladbach, Allemagne

Vendeur avec une évaluation de 5 étoiles

Vendeur AbeBooks depuis 11 janvier 2012

Frais d'expédition de Allemagne vers Etats-Unis

Article5 à 15 jours ouvrés5 à 15 jours ouvrés
Premier articleEUR 23,00EUR 23,00
Les délais de livraison sont fixés par les vendeurs et varient en fonction du transporteur et du lieu. Les commandes transitant par les douanes peuvent être retardées et les acheteurs sont responsables de tous les droits ou frais associés. Les vendeurs peuvent vous contacter au sujet de frais supplémentaires afin de couvrir toute augmentation des coûts d'expédition de vos articles.

Modes de paiement

  • Visa
  • Mastercard
  • American Express
  • Carte Bleue
  • Apple Pay
  • Google Pay
  • Chèque
  • Paypal
  • Virement bancaire

Profil professionnel du vendeur

BuchWeltWeit Ludwig Meier e.K.

Allemagne

BuchWeltWeit Inh. Ludwig Meier e.K.
Inhaber: Ludwig Meier
De-Gasperi-Str. 8
51469 Bergisch Gladbach
Deutschland

Tel.: +49(0)22028659300
Fax: +49(0)22028659301
E-Mail: info@buchweltweit.de

Registergericht: Amtsgericht Köln
Registernummer: HRA 28253

Umsatzsteuer-Identifikationsnummer: DE815259907

Wir sind zur Teilnahme an einem Streitbeilegungsverfahren vor einer Verbraucherschlichtungsstelle weder verpflichtet noch bereit.