Molecular Alternatives to Indicator and Pathogen Detection (Paperback)

Langue : anglais

Edité par IWA Publishing, London, 2006

1843397358 / 9781843397359

  • Éd. originale
  • Livre broché
  • Neuf
Afficher toutes les informations

Vendeur : Grand Eagle Retail, Bensenville, IL, Etats-UnisGrand Eagle Retail

Vendeur avec une évaluation de 5 étoiles

Vendeur AbeBooks depuis 12 octobre 2005

Livre broché

Etat: Neuf

EUR 183,73

 Frais de port gratuits 
Expédition nationale : Etats-Unis

Quantité disponible : 1 disponible

Ajouter au panier
Retours gratuits sous 30 jours

A propos de cet article

Paperback. Microbial quality of water is a prime public health concern in today's world. To protect public health, the World Health Organization and the U.S. Environmental Protection Agency have established microbial pollution indicator standards and recommended routine monitoring of water for both total and fecal coliforms. However, the adequacy of current water quality standards to indicate the presence or absence of human pathogens is still questionable. For example, human viruses are more resistant to sewage treatment processes and environmental conditions than bacterial indicators and therefore may pose a substantial threat. It is now recognized that the absence, or a low concentration, of indicator organisms in water may not adequately reflect the absence of human viruses. In our previous study of southern California coastal waters, we found over 30% of coastal waters tested contained human viruses, and the presence of these viruses did not correlate with an elevated level of bacterial indicators (Jiang et al. 2000). The goal of this research is to develop and validate a molecular method for rapid and specific detection of microbial contaminants including human viruses and bacterial indicators in treated sewage effluents and receiving waters. Microbial quality of water is a prime public health concern in today's world. To protect public health, the World Health Organization and the U.S. Environmental Protection Agency have established microbial pollution indicator standards and recommended routine monitoring of water for both total and fecal coliforms (Dufour, 1984, U.S. EPA 1986,1994, WHO 1993). However, the adequacy of current water quality standards to indicate the presence or absence of human pathogens is still questionable. For example, human viruses are more resistant to sewage treatment processes and environmental conditions than bacterial indicators and therefore may pose a substantial threat. It is now recognized that the absence, or a low concentration, of indicator organisms in water may not adequately reflect the absence of human viruses. In our previous study of southern California coastal waters, we found over 30% of coastal waters tested contained human viruses, and the presence of these viruses did not correlate with an elevated level of bacterial indicators (Jiang et al. 2000). The goal of this research is to develop and validate a molecular method for rapid and specific detection of microbial contaminants including human viruses and bacterial indicators in treated sewage effluents and receiving waters. Research Outcomes An extensive search and review of current state of technology for molecular alternatives to indicator and viral pathogen detection was conducted. The results indicate that although real-time PCR methods have been widely applied in the clinical research for detection of human viruses, environmental application of this method is very limited. In addition, there is an urgent need for a method for efficient concentration and purification of human viruses in complex environmental matrixes. During this study, we have designed, tested and optimized real-time quantitative PCR method using specific and degenerate primers and probes targeting at adenoviruses and enterococci, respectively. Experimental testing of real time PCR primers and probes for adenoviruses demonstrated reproducible results at efficiency greater than 90% over a 5-log dynamic range of target concentration. The enterococci real time PCR was efficient at 99% of the time and over a 7-log dynamic range of target concentration. Application of these methods to sewage effluents and coastal waters demonstrated that real-time PCR methods are more sensitive than culturing methods at detection of targets, suggesting a great potential for real-time quantification of microbial contaminants in environments. However, real-time PCR based meth Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…

N° de réf. du vendeur 9781843397359

Titre
Molecular Alternatives to Indicator and Pathogen Detection (Paperback)
Auteur
S.C. Jiang
Éditeur
IWA Publishing, London
Année de publication
2006
État de l'article
new
Reliure
Paperback
Langue
anglais
ISBN à 10 chiffres
1843397358
ISBN à 13 chiffres
9781843397359
Édition
Edition originale

Grand Eagle Retail

Bensenville, IL, Etats-Unis

Vendeur avec une évaluation de 5 étoiles

Vendeur AbeBooks depuis 12 octobre 2005

Frais d'expédition à l'intérieur de ce pays : Etats-Unis

Article6 à 14 jours ouvrés6 à 16 jours ouvrés
Premier articleEUR 0,00EUR 0,00
Les délais de livraison sont fixés par les vendeurs et varient en fonction du transporteur et du lieu. Les commandes transitant par les douanes peuvent être retardées et les acheteurs sont responsables de tous les droits ou frais associés. Les vendeurs peuvent vous contacter au sujet de frais supplémentaires afin de couvrir toute augmentation des coûts d'expédition de vos articles.

Modes de paiement

  • Visa
  • Mastercard
  • American Express
  • Carte Bleue
  • Apple Pay
  • Google Pay

Profil professionnel du vendeur

APOLLO ONLINE CORP.

605 Geddes Street
Wilmington, DE Etats-Unis 19805