Radiation Beam Collimation Used In Radiotherapy: Radiotherapy. Cet article n’est pas disponible.
Langue : anglais
Edité par Lap Lambert Academic Publishing, 2012
- Livre broché
- Neuf

Vendeur : Revaluation Books, Exeter, Royaume-UniRevaluation Books
Vendeur avec une évaluation de 5 étoiles
Vendeur AbeBooks depuis 6 janvier 2003
Indisponible
Livre broché
Etat: Neuf
EUR 133,28
A propos de cet article
168 pages. 8.66x5.91x0.38 inches. In Stock.
N° de réf. du vendeur 3659280496
- Titre
- Radiation Beam Collimation Used In Radiotherapy: Radiotherapy
- Auteur
- Hegazy, Ehab; Kamal, Moustafa; Dawod, Tamer; Hegazy, Ehab; Kamal, Moustafa; Dawod, Tamer
- Éditeur
- Lap Lambert Academic Publishing
- Année de publication
- 2012
- État de l'article
- Brand New
- Reliure
- Paperback
- Langue
- anglais
- ISBN à 10 chiffres
- 3659280496
- ISBN à 13 chiffres
- 9783659280498
- Poids de l'article
- 0,3 kilogramme
The objectives of this study are to investigate and compare the dose distribution defined with divergent cerrobend alloy custom blocks to the distribution obtained with multileaf collimator (MLC) provided by high energy linear accelerator. The study was made for simple block replacement situations. Prior to making the comparison, multileaf collimator performance checks will be made. These checks include the following measurements: leaf Attenuation, leaf transmissions, in-between-leaf leakage properties and measurement of tongue and groove effect. By using of ionization chamber in water phantom, percent depth dose, beam flatness, symmetry, penumbra, leaf transmission and leakage will be measured. By using of radiographic films the transmission, penumbra, and verification of leaf position and leaf motion will be determined . Finally output factor of both multileaf collimator and cerrobend block will be measured same field sizes at the same conditions of dosimetry. The final aim of this study to improve the accuracy of cancer treatment delivery
« Synopsis » peut appartenir à une autre édition de cet ouvrage.
Présentation de l'éditeur
The objectives of this study are to investigate and compare the dose distribution defined with divergent cerrobend alloy custom blocks to the distribution obtained with multileaf collimator (MLC) provided by high energy linear accelerator. The study was made for simple block replacement situations. Prior to making the comparison, multileaf collimator performance checks will be made. These checks include the following measurements: leaf Attenuation, leaf transmissions, in-between-leaf leakage properties and measurement of tongue and groove effect. By using of ionization chamber in water phantom, percent depth dose, beam flatness, symmetry, penumbra, leaf transmission and leakage will be measured. By using of radiographic films the transmission, penumbra, and verification of leaf position and leaf motion will be determined . Finally output factor of both multileaf collimator and cerrobend block will be measured same field sizes at the same conditions of dosimetry. The final aim of this study to improve the accuracy of cancer treatment delivery
« A propos de ce titre » peut appartenir à une autre édition de cet ouvrage.